Previous | Next | DMIS
Topic: Composite GDAT
Conf: DMIS, Msg: 311
From: Ray Admire (ray.admire@lmco.com)
Date: 8/29/1998 09:46 AM

Many of the plates that we inspect have a hole pattern which have a composite tolerance. Pos. to A, B & C @ .030 and pattern to itself within .010. In WinCMES we would use D variables to average the X & Y and move the origin and re-compute the pattern to the new origin. The DMIS standard has a composite command that is not recognized by LK-DMIS. How do other companies calculate composite tolerances within LK-DMIS?
When will this command be usable within LK-DMIS.
Are the same D-variables Available within LK-DMIS.


Ray Admire
Quality Engineer, CMM Programming
Lockheed Martin Vought Systems